CPD digital load cell

CPD digital load cell

  • Also in ATEX version for gas and dust
  • for highest accuracy requirements and best service
  • available load ranges 20 / 35 / 50 t
  • calibratable up to 6000 parts according to 90/384 EEC
  • Corresponds to OIML recommendation R60
  • Stainless steel housing
  • Pluggable lines via cable plug connection
  • EMC tested
  • Integrated active and passive overvoltage protection
  • self-righting function
  • Data transmission via digital output signal RS 485
  • digital temperature compensation
  • Protection class IP 68 (DIN 40050)
  • Operating temperature range -30°C to +70°C

Technical data

Accuracy class C          C1                 C2                  C3                 C4                 C5                 C6       
Nominal load (Emax)   (t)    20 / 35 / 50
Maximum pitch value (nmax)   1000 2000 3000 4000 5000 6000
Maximum division factor Y value (Emax / Vmin)        5000 7000 18000 18000 20000 20000
Weight (kg)   approx. 3   
Material   Stainless steel
Protection class ATEX load cell   II 1 GD [EEx ia] IIC T5 IP 66 T100°C
Protection type ATEX safety barrier   II (1) GD [EEx ia] IIC
Load cell distributor terminal box for digital load cells CPD
  • Protection class IP 68
  • With additional surge arresters for easy service
  • with 8 pluggable connections for bus-compatible, digital load cells